Toll-free: (888)-TRERICE (873-7423) sales@trerice.com

Mini & Compact

Diaphragm Seals

866 It is recommended to place a needle valve, ball valve or gauge cock in line before every pressure gauge installation.

Selection of the proper diaphragm seal is the sole responsibility of the user. Temperature and pressure limitations must be considered. Please refer to the Diaphragm Seal Design & Operation Section of this catalog. Improper application may cause failure of the seal, resulting in possible personal injury or property damage.

 For correct use and application of all diaphragm seals, please refer to Diaphragm Seal Standard ASME B40.2.

How to Order

Dimensional Drawings

Complete Specifications

ModelsWetted Parts
D82B (dry)
D82LFB (liquid-filled)
Bronze tube, brass socket
Lead-Free (PBF)
Meets NSF/ANSI
Standards 372 and 61
D83SS (dry)
D83LFSS (liquid-filled)
316 Stainless steel tube & socket
Dial Size1½", 2", 2½", 4"
FillGlycerine. Other fills available.
See Options & Accessories.
MovementD82: Brass
D83: 316 Stainless steel
ConnectionLower male or center back male,
(Lower back male 4" Dial only)
Case304 stainless steel, satin finished, stem-mounted flangeless
RingCrimped 304 stainless steel
WindowAcrylic
PointerPlain, black finished
Dial FaceAluminum, white background with black graduations and markings
Accuracy±1.6% Full Scale
(1% available as an option)
Maximum Temperature150°F (65°C)
Approximate Shipping Weight1½" Dial Size:
0.4 lbs [0.18 kg]

2" Dial Size:
0.4 lbs [0.18 kg]

2½" Dial Size:
0.5 lbs [0.23 kg]

4" Dial Size:
1.0 lbs [0.45 kg]

Design and Operations

Options and Accessories

Download PDF